UL 1642 Lithium Battery Acupuncture Tester Force Range 3000N Battery Testing Equipment
Product information:
The tester is used to simulate the conditions in which various types of batteries are exposed to needle puncture when used, transported, stored or disposed of household waste.
The test should be carried out at an ambient temperature of 20℃±5℃, and the battery connected to the thermocouple (the contact of the thermocouple is fixed on the large surface of the battery) is placed in a fume hood. Use a non-corrosive steel needle with a diameter of 2-8mm to pierce the center of the largest surface of the battery at a speed of 10mm/s to 40mm/s, hold it for any time and observe the test results. If the battery does not explode or catch fire, it is considered qualified.
Parameters:
Item | Parameters |
Power supply | AC220V±10%/50Hz |
Test station | Single station |
Operation interface | 7-inch color LCD touch screen |
Drive mode | Servo Motor |
Control method | PLC Control |
Test force range | 0~3000N |
Residence time | 0~9999.9s, can be preset |
Test stroke | 0~200mm, can be preset |
Test speed | 0~40mm/s, can be preset |
Test environment | Atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~90)%RH. Use place: no violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gas, good heat dissipation |
Τροποποιημένο: | 1 |
τιμή: | Customized |
Τυπική συσκευασία: | Plywood Case |
Περίοδος παράδοσης: | 30 days |
Μέθοδος πληρωμής: | T/T |
Ικανότητα εφοδιασμού: | 5 Sets Per Month |
UL 1642 Lithium Battery Acupuncture Tester Force Range 3000N Battery Testing Equipment
Product information:
The tester is used to simulate the conditions in which various types of batteries are exposed to needle puncture when used, transported, stored or disposed of household waste.
The test should be carried out at an ambient temperature of 20℃±5℃, and the battery connected to the thermocouple (the contact of the thermocouple is fixed on the large surface of the battery) is placed in a fume hood. Use a non-corrosive steel needle with a diameter of 2-8mm to pierce the center of the largest surface of the battery at a speed of 10mm/s to 40mm/s, hold it for any time and observe the test results. If the battery does not explode or catch fire, it is considered qualified.
Parameters:
Item | Parameters |
Power supply | AC220V±10%/50Hz |
Test station | Single station |
Operation interface | 7-inch color LCD touch screen |
Drive mode | Servo Motor |
Control method | PLC Control |
Test force range | 0~3000N |
Residence time | 0~9999.9s, can be preset |
Test stroke | 0~200mm, can be preset |
Test speed | 0~40mm/s, can be preset |
Test environment | Atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~90)%RH. Use place: no violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gas, good heat dissipation |